fbpx

Mitsubishi Generator Series

Official Australian distributor

CAPS are partnered with Mitsubishi Heavy Industries Engine System Asia (MHIES-A) as the official Australian distributor for the Mitsubishi Generator Series (MGS).

 

MGS-R SERIES

Mitsubishi Diesel Generator “MGS-R” Series is designed and built with state-of-the-art capabilities in one model, making it the “All-In-One” Series.

A key strength of the Mitsubishi Generator Series is the utilisation of Mitsubishi Heavy Industries’ renowned diesel engines.

Meticulously crafted in Japan with globally-recognised Mitsubishi Engines, Mitsubishi Turbochargers, advanced control systems, and a top quality brand of alternators, the MGS delivers reliable and excellent in performance, supplying power during emergencies and acting as a backup for critical operations.

Download Brochure

Photo

MGS-R diesel engines deliver outstanding performance in fuel efficiency and reduced emissions.

  • Power output from 385kVA to 3025kVA
  • Data center specific power output ratings
  • Data Centre Tier III/IV certified from the Uptime Institute
  • ISO8528 G3 transient performance standards
  • ANSI/TIA942 rating from Rated 1 to Rated 4

With a strong focus on innovation and advanced technology, the Mitsubishi Generator Series is engineered to meet the demanding requirements of diverse sectors, including industrial, commercial, construction, and emergency backup power needs.

Contact us to learn more about a customised power engineering solution for your company.
To discuss your unique project with one of the CAPS team, give us a call on 1800 800 878.

Mitsubishi diesel engine

The Mitsubishi Diesel Engine is equipped with a range of standard features that exemplify quality and performance. At its core, the engine boasts robust construction and advanced engineering, ensuring durability and reliability in even the most demanding applications.

This series is engineered with quick-start ability within 10 seconds and 100 per cent one-step load capability, demonstrating its reliability in demanding situations. Moreover, the MGS-R Series adheres to seismic design codes, ensuring approval for use in the harshest applications.

Photo

Power core

With precision fuel injection systems, the engine delivers optimal fuel efficiency and reduced emissions, contributing to a greener and more sustainable operation. Additionally, integrated cooling systems effectively manage the engine’s temperature, ensuring optimal performance in various operating conditions.

Photo

AC GENERATOR

  • Fully Sealed
  • 3 phase RMS sensing DAVR with built-in protection against sustained over-excitation
  • Voltage regulation:
    Less than +/- 0.5% from no load to full load at any power factor between 0.8 lagging and 1.0.
    Allowing for a 4% engine speed variation
  • ISO 8528-3, IEC60034-1 / BS EN60034-1, BS5000 PART 3,VDE0530, NEMA MG1-32, CSA22-2-100, AS1359 AND UL1446
Photo

Control Panel

The Mitsubishi Generator Series standard 7310 features a programmable microprocessor control that serves as an automatic start/stop panel, complete with generator breaker control.
This effectively indicates operational status and detects any fault conditions, while the LCD display and LEDs on the front panel promptly indicate engine failure and automatically initiate shutdown.
The electrical design meets the standards of BS EN 60950 Low Voltage Directive, BS EN 61006-2, and 61006-4 EMC Directive, and optional interfaces provide realtime diagnostic capabilities.

FOR EVERY POWER REQUIREMENT

Mitsubishi Heavy Industries, is constantly striving to develop cutting-edge solutions that promote sustainable energy and reduce environmental impact. The MGS-R, is a revolutionary Mitsubishi Diesel Generator designed with compatibility for Hydrotreated Vegetable Oil (HVO). Powered by HVO fuel, your organisation can embrace sustainability, reduce carbon emissions, and contribute to a cleaner and more sustainable future.

 

* Average load factor (per 24Hr or year) shall be calculated as per the formula in ISO 8528-1:2018 ‘average power output (Ppp)’.
* UPTIME compliant: Both CP and DCCP rating meets the requirement of a Tier III and Tier IV data center site with no runtime limitation when the operation is loaded to ‘N’ demand for the engine generator set.
* 10% overload is not recognized by Uptime for Tier Certification. Agreement between manufacturer and customer when use in tier system.
* DCCP rating does not have +10% overload defined in ISO 8528-1:2018.
*Please approach our authorised dealer/distributor for other voltage ratings (i.e. Medium/High Voltage) and output rating when using HVO.
1. Generator is 3 Phase 4 wire (star connection), Class H insulation and temperature rise 125°C (DCCP/PRP)/ 150 °C (CP/ESP).
2. Genset operating conditions is assumed 40 °C ambient temperature and altitude is 1000 meters ASL (Above Sea Level).
3. Rated Power factor is 0.8 Lagging.

Contact us

General Enquiry

  • Hidden
  • Hidden

Book a Service

  • DD slash MM slash YYYY
  • Attach File (Please include a picture of the data plate or the machine if available)

    Drop files here or
    Max. file size: 64 MB.

    Quote a Request